Remote and Safe Monitoring of Magnetic Fields Produced by Transmission Lines in Areas of High Concentration of Lightning Strokes

Authors

  • Carlos Alberto T. Carvalho Jr Universidade Federal de Rondônia
  • Ciro J. Egoavil Universidade Federal de Rondônia
  • Frank Gonzatti Federal University of Santa Maria
  • Felix A. Farret Federal University of Santa Maria

DOI:

https://doi.org/10.31686/ijier.vol6.iss2.953

Keywords:

Magnetic field monitoring, overhead transmission lines, lightning stroke areas, monitoring electromagnetic waves

Abstract

Monitoring of magnetic and electric fields in high voltage transmission lines (HVTL) of power plants and substations (SEs) is contemplated by Brazilian Regulatory Standard 616/2014. The measurement procedures of the magnetic and electric fields in SEs must follow a methodology in case of continuous field monitoring of the power equipment where it is common lightning stroke incidences. These monitoring procedures must be carried out in such a way that the recording of electromagnetic fields is done without necessity of exposuring the technical team to irradiation from the equipment and machines generating electrical power. This paper describes a prototype which is able to produce data at a specified safe distance from the irradiating area. The experimental recorded data was acquired, processed, compared and analyzed in areas of more intense radiation levels, acceptable levels and safe levels. This work aimed to establish basis of a technological innovation for the continuous recording of electromagnetic data, trying to cover the surroundings of transmission lines in urban environments, close to the generating units and substation installations wherever the highest levels of magnetic field could be found.

Downloads

Download data is not yet available.

References

[1] R. Kavet, M. A. Stuchly, W. H. Bailey, and T. D. Bracken, “Evaluation of biological effects, dosimetric models, and exposure assessment related to ELF electric- and magnetic-field guidelines,” Appl Occup Env. Hyg, vol. 16, no. 12, pp. 1118–1138, 2001.

[2] H. Jia, “The influence of extremely low-frequency magnetic field and magnetic nanoparticle on A β40 aggregation in Vitro,” IEEE Trans. Electromagn., vol. 51, no. 11, p. 2015, 2015.

[3] Y. Cui, X. Liu, T. Yang, Y.-A. Mei, and C. Hu, “Exposure to extremely low-frequency electromagnetic fields inhibits T-type calcium channels via AA/LTE4 signaling pathway.,” Cell Calcium, vol. 55, no. 1, pp. 48–58, 2014.

[4] A. Komaki, A. Khalili, I. Salehi, S. Shahidi, and A. Sarihi, “Effects of exposure to an extremely low frequency electromagnetic field on hippocampal long-term potentiation in rat,” Brain Res., vol. 1564, pp. 1–8, 2014.

[5] T. Barsam, M. R. Monazzam, A. A. Haghdoost, M. R. Ghotbi, and S. F. Dehghan, “Effect of extremely low frequency electromagnetic field exposure on sleep quality in high voltage substations.,” Iranian J. Environ. Health Sci. Eng., vol. 9, no. 1, p. 15, 2012.

[6] IARC, Working Group on the Evaluation of Carcinogenic Risks to Humans and World Health Organization and International Agency for Research on Cancer. Non-ionizing Radiation: Static and extremely low-frequency (ELF) electric and magnetic fields, vol. 80. Lyon, France: World Health Organization, 2002.

[7] N. McNelis, “EU communications on the precautionary principle,” J. Int. Econ. Law, vol. 3, no. February 1998, pp. 545–551, 2000.

[8] ICNIRP, “ICNIRP statement on the ‘guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 ghz),’” Health Phys., vol. 74, no. 4, pp. 494–522, 1998.

[9] ICNIRP, “Guidelines for Limiting Exposure to Time-Varying Electric and Magnetic Fields (1Hz to 100 KHz),” Health Phys., vol. 99, no. 1, p. 112, 2010.

[10] J. Swanson, “Power-frequency EMF Exposure Standards applicable in Europe and elsewhere,” 2014. [Online]. Available: http://www.emfs.info/wp-content/uploads/2014/07/standards-table-revision-5l-July-2014.pdf.

[11] J. Liu, W. Ruan, S. Fortin, and F. P. Dawalibi, “Electromagnetic fields near high voltage electrical power lines: a parametric analysis,” in Power System Technology, 2002. Proceedings. PowerCon 2002. International Conference on, 2002, vol. 1, pp. 401–408.

[12] A. H. Khawaja and Q. Huang, “Characteristic estimation of high voltage transmission line conductors with simultaneous magnetic field and current measurements,” 2016 IEEE International Instrumentation and Measurement Technology Conference Proceedings. pp. 1–6, 2016.

[13] M. D. J. Roscoe, N. M. and and L. Fraser, “A Novel Inductive Electromagnetic Energy Harvester For Condition Monitoring Sensors,” in Proceedings of the 2010 International Conference on Condition Monitoring and Diagnosis -CMD 2010, Tokyo, Japan, September 6 - 11, 2010, pp. 615–618.

[14] X. Sun, Q. Huang, L. J. Jiang, and P. W. T. Pong, “Overhead high-voltage transmission-line current monitoring by magnetoresistive sensors and current source reconstruction at transmission tower,” IEEE Trans. Magn., vol. 50, no. 1, 2014.

[15] N. M. Roscoe and M. D. Judd, “Harvesting Energy From Magnetic Fields to Power Condition Monitoring Sensors,” IEEE Sens. J., vol. 13, no. 6, pp. 2263–2270, 2013.

[16] ONS, “Operador Nacional do Sistema. Mapas de Densidade de Descargas Atmosféricas,” 30 de setembro 2015, 2015. [Online]. Available: http://www.ons.org.br/conheca_sistema /mapas_sin.aspx. [Accessed: 15-Nov-2016].

Downloads

Published

2018-02-01

How to Cite

Carvalho Jr, C. A. T. ., Egoavil, C. J. ., Gonzatti, F. ., & Farret, F. A. . (2018). Remote and Safe Monitoring of Magnetic Fields Produced by Transmission Lines in Areas of High Concentration of Lightning Strokes. International Journal for Innovation Education and Research, 6(2), 99-115. https://doi.org/10.31686/ijier.vol6.iss2.953